Short answer: Florida enforces ASME A17.1-2019, which adds two-way text messaging and video to elevator emergency communication so trapped passengers who cannot hear or speak can still get help. It applies to new elevators and can be triggered by modernizations and other alterations. IEI explains what your buildings actually need and reviews upgrade proposals before you sign.

What the code requires

  • Two-way voice communication between the car and authorized emergency personnel
  • Two-way text messaging, shown at the car's emergency phone panel, so passengers who cannot hear or speak can communicate
  • Video of the car interior available to authorized emergency personnel
  • In buildings with an elevator rise of 60 feet or more, a separate communication point at the designated landing for first responders in the building

Why this is coming up now

Florida's Bureau of Elevator Safety adopted ASME A17.1-2019, A17.3-2020 and A18.1-2020 through Rule 61C-5.001, F.A.C., and re-adopted them in May 2026. These are the same editions the 9th edition of the Florida Building Code enforces when it takes effect on December 31, 2026. As more buildings modernize under the new code, video and text communication is becoming standard.

At the same time, phone carriers are retiring traditional copper landlines that many elevator phones still use, so many buildings are replacing their elevator communication equipment anyway.

Does every existing elevator have to be upgraded?

Not automatically. New installations must comply. For existing elevators, the requirement is usually triggered by an alteration, such as a modernization or replacing the emergency communication system, and the exact trigger depends on the scope of work and your authority having jurisdiction. Be cautious of any proposal that presents an upgrade as mandatory without citing the code section and the work that triggers it.

How IEI helps

  1. Review each elevator's current emergency communication equipment and phone line
  2. Confirm what is required now, what is triggered by planned work, and what is optional
  3. Review contractor proposals for scope and price before you sign
  4. Write the requirement into modernization specifications so every bidder prices it
  5. Witness testing of the new system and confirm it is accepted by your AHJ

Frequently asked questions

Do I have to add video and text to my existing elevators in Florida?

Not automatically. Florida enforces ASME A17.1-2019 for new installations and for alterations that trigger it, such as a modernization or a replacement of the emergency communication system. Whether a specific elevator must be upgraded depends on the work being done and your authority having jurisdiction, so have the requirement confirmed before you approve a proposal.

When does the 9th edition of the Florida Building Code take effect?

December 31, 2026. It enforces the same elevator code editions Florida's Bureau of Elevator Safety has adopted: ASME A17.1-2019, A17.3-2020 and A18.1-2020.

Why are elevator phone lines being replaced?

Phone carriers are retiring the traditional copper landlines many elevator phones use. Many buildings are moving to cellular or other digital communication, which is also a good time to plan for the newer video and text requirements.